21
English RAIS - manual for RAIS 500
PRELEMINARY
PRELEMINARY
To guide the hot air out of the
gratings, we recommends to
install a non-flammable plate
just above the holes.
It is recommended to knock out the 3
areas - prepared for heat transfer - out.
Distance to furniture
min. 900 mm
Min. 100 mm
Installation distance in case of combustible wall
To find out whether the wall next to where the stove is going to be installed is flammable,
you should contact your building contractor or the local building authorities.
The hearth should be able to accommodate the weight of the stove. The chimney must
be independently supported by wall brackets or a ceiling support plate. The weight of the
stove is indicated in the brochure.
The stove should always be installed on a non-combustible hearth of a size and construc-
tion that is in accordance with the provisions of the current UK Building Regulations Ap-
proved Document J.
If the stove is to be installed on a wooden floor, it must be covered with a noncombustible
material at least 12mm thick, in accordance with UK Building Regulations Approved Docu-
ment J, to a distance of 300 mm in front of the stove and 150 mm to each side measuring
from the door of the combustion chamber.
The clearance distances to combustible material beneath, surrounding or upon the hearth
and walls adjacent to the hearth should comply with the guidance on the separation of
combustible material given in UK Building Regulations Approved Document J and also in
these stove instructions.
For the Installer
Finally before firing the stove for the first time a check should be made to ensure that the
assembly and stove installation has been satisfactory and that there are no leaks in any
seals in the appliance and appliance connections to the chimney.
Ensure that the appliance and chimney flue are functioning correctly before finally hand-
ing over to the user. If necessary read the later parts of this manual for guidance on care
required when first lighting.
Inform the user that the appliance has been commissioned and ready to use and give
instruction on the safe operation of the stove.
These Instructions must be left with the user and the user should be instructed to keep
them in a safe place.
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 35 36

Komentarze do niniejszej Instrukcji

Brak uwag

Asb-heating-elements-ltd 8” Flange Heaters - 25 watts - Incoloy Sheath manuals

Owner’s manuals and user’s guides for Hardware Asb-heating-elements-ltd 8” Flange Heaters - 25 watts - Incoloy Sheath.
We providing 1 pdf manuals Asb-heating-elements-ltd 8” Flange Heaters - 25 watts - Incoloy Sheath for download free by document types: User Manual






More products and manuals for Hardware Asb-heating-elements-ltd

Models Document Type
3” & 4” Flange Heaters - 25 watts - Steel Shea User Manual   ASB Heating Elements Ltd. 3” & 4” Flange Heaters - 25 watts - Steel Sheath User Manual, 1 pages
5” & 6” Flange Heaters - 25 watts - Incoloy Sh User Manual   ASB Heating Elements Ltd. 5” & 6” Flange Heaters - 25 watts - Incoloy Sheath User Manual, 1 pages
8” Flange Heaters - 50-60 watts - Incoloy Sheath User Manual   ASB Heating Elements Ltd. 8” Flange Heaters - 50-60 watts - Incoloy Sheath User Manual, 1 pages
3” & 4” Flange Heaters - 25 watts - Incoloy Sh User Manual   ASB Heating Elements Ltd. 3” & 4” Flange Heaters - 25 watts - Incoloy Sheath User Manual, 1 pages
8” Flange Heaters - 50-60 watts - Copper Sheath User Manual   ASB Heating Elements Ltd. 8” Flange Heaters - 50-60 watts - Copper Sheath User Manual, 1 pages
5” & 6” Flange Heaters - 50-60 watts - Incoloy User Manual   ASB Heating Elements Ltd. 5” & 6” Flange Heaters - 50-60 watts - Incoloy Sheath User Manual, 1 pages
3” & 4” Flange Heaters - 50-60 watts - Incoloy User Manual   ASB Heating Elements Ltd. 3” & 4” Flange Heaters - 50-60 watts - Incoloy Sheath User Manual, 1 pages
5” & 6” Flange Heaters - 50-60 watts - Copper User Manual   ASB Heating Elements Ltd. 5” & 6” Flange Heaters - 50-60 watts - Copper Sheath User Manual, 1 pages
Duct Heater User Manual   ASB Heating Elements Ltd. Duct Heater User Manual, 1 pages
3” & 4” Flange Heaters - 50-60 watts - Copper User Manual   ASB Heating Elements Ltd. 3” & 4” Flange Heaters - 50-60 watts - Copper Sheath User Manual, 1 pages
Pipe Insert Heater User Manual   ASB Heating Elements Ltd. Pipe Insert Heater User Manual, 2 pages
Over-the Side Immersion Heaters User Manual   ASB Heating Elements Ltd. Over-the Side Immersion Heaters User Manual, 5 pages
Strip Heaters High Density Compacted MgO User Manual   ASB Heating Elements Ltd. Strip Heaters High Density Compacted MgO User Manual, 2 pages
Strip Heaters Mica Insulated User Manual   ASB Heating Elements Ltd. Strip Heaters Mica Insulated User Manual, 2 pages
Radiant Heaters User Manual   ASB Heating Elements Ltd. Radiant Heaters User Manual, 4 pages
Miscellaneous Accessories User Manual   ASB Heating Elements Ltd. Miscellaneous Accessories User Manual, 1 pages
Cartridge Heaters User Manual   ASB Heating Elements Ltd. Cartridge Heaters User Manual, 14 pages
Mercury Relays User Manual   ASB Heating Elements Ltd. Mercury Relays User Manual, 1 pages
Solid State Relays User Manual   ASB Heating Elements Ltd. Solid State Relays User Manual, 1 pages
Thermocouples - Adjustable Bayonet User Manual   ASB Heating Elements Ltd. Thermocouples - Adjustable Bayonet User Manual, 10 pages