When the fire has caught the kindling (4) close the door completely (after approx. 5
min.).
When the temperature reaches a certain value, the damper will divert the smoke.
This causes a downward flame from the upper to the lower combustion chamber
LCC (5-6).
When the last flames are extinguished and there is a nice layer of embers (7), add
1-2 pieces wood - about 1-1 ½ kg (8). Place the wood on top of the dome at the
rear of the UCC! Close the door completely.
NOTE!
If the fire has burned down too low (too small an ember), it may take longer time for the
flames to be diverted to the LCC and thus achieve a cleaner burn.
When firing the smoke out of the chimney should be almost invisible; just a ’flicker’ in the
air is opserved.
When refueling, open the door carefully to avoid smoke escaping. Never add wood while
it is burning (flames!) in the stove.
RAIS recommends to refuel with 1-2 pieces wood - approx. 1-1 ½ kg - within 1½ hours
(intermittent operation).
ATTENTION!!!
Keep an eye on the stove when lighting. During operation the door should always remain
shut.
Control
Look for signs that indicates a correct firing in the stove:
ash is white
the walls of the combustion chamber is free of soot
the wood is sufficiently dry